24 hours online support our customer.replacing a multi-lined selection of text.
Uni Flex Cables Industries.
Nominal Cross Section Area of Conductor – – (Sqmm) | Maximum Diameter of Stranding Wire in Conductor – – (mm) | Nominal Thickness of PVC Insulation – – (mm) | 2Core | 3Co | re | 4Core | ||
Nominal Thickness of Outer Sheath – (mm) | Approximate Overall Cable Diameter – (mm) | Nominal Thickness of Outer Sheath – (mm) | Approximate Overall Cable Diameter – (mm) | Nominal Thickness of Outer Sheath – (mm) | Approximate Overall Cable Diameter – (mm) | |||
1.50 | 0.26 | 0.80 | 1.60 | 9.50 | 1.60 | 10.30 | 1.60 | 11.15 |
2.50 | 0.26 | 0.80 | 1.60 | 10.80 | 1.60 | 11.32 | 1.60 | 12.28 |
4.00 | 0.31 | 1.00 | 1.60 | 12.60 | 1.60 | 13.32 | 1.80 | 14.90 |
6.00 | 0.31 | 1.00 | 1.80 | 14.15 | 1.80 | 15.00 | 1.80 | 16.35 |
10.00 | 0.41 | 1.00 | 1.80 | 16.00 | 1.80 | 16.98 | 1.80 | 18.56 |
16.00 | 0.41 | 1.00 | 1.80 | 19.56 | 1.80 | 20.80 | 1.80 | 22.86 |
25.00 | 0.41 | 1.20 | 2.00 | 23.70 | 2.00 | 25.20 | 2.00 | 27.75 |
35.00 | 0.41 | 1.20 | 2.00 | 26.52 | 2.00 | 28.30 | 2.00 | 31.20 |
50.00 | 0.41 | 1.40 | 2.00 | 30.55 | 2.00 | 32.65 | 2.20 | 36.56 |
70.00 | 0.51 | 1.40 | 2.20 | 35.05 | 2.20 | 37.50 | 2.20 | 41.45 |
Nominal Cross Section Area of Conductor (Sqmm) | Maximum Diameter of Stranding Wire in Conductor (mm) | Nominal Thickness of PVC Insulation (mm) | 2Core | 3Core | 4Core | |||
Nominal Thickness of Outer Sheath (mm) | Approximate Overall Cable Diameter (mm) | Nominal Thickness of Outer Sheath (mm) | Approximate Overall Cable Diameter (mm) | Nominal Thickness of Outer Sheath (mm) | Approximate Overall Cable Diameter (mm) | |||
1.50 | 0.26 | 0.70 | 1.60 | 9.50 | 1.60 | 9.90 | 1.60 | 10.65 |
2.50 | 0.26 | 0.80 | 1.60 | 10.80 | 1.60 | 11.40 | 1.60 | 12.35 |
4.00 | 0.31 | 0.80 | 1.60 | 11.70 | 1.60 | 12.36 | 1.60 | 13.45 |
6.00 | 0.31 | 0.80 | 1.60 | 12.80 | 1.60 | 13.60 | 1.80 | 15.30 |
10.00 | 0.41 | 1.00 | 1.80 | 15.60 | 1.80 | 16.55 | 1.80 | 18.10 |
16.00 | 0.41 | 1.00 | 1.80 | 17.60 | 1.80 | 18.70 | 1.80 | 20.50 |
25.00 | 0.41 | 1.00 | 2.00 | 21.00 | 2.00 | 22.35 | 2.00 | 24.55 |
Nominal CSA of Conductor & Nos. of Cores (Sqmm x Cores) | Maximum Diameter of Stranding Wire in Conductor (mm) | Nominal Thickness of PVC Insulation – (mm) | Nominal Thickness of Outer Sheath – (mm) | Overall Diameter | Weight of Finished Cable Approx – (Kg/KM) | |
Minimum (mm) | Maximum (mm) | |||||
0.50 x 2 | 0.21 | 0.60 | 0.80 | 5.60 | 7.00 | 50 |
0.75 x 2 | 0.21 | 0.60 | 0.80 | 5.70 | 7.20 | 54 |
1.00 x 2 | 0.21 | 0.60 | 0.80 | 5.90 | 7.50 | 68 |
1.50 x 2 | 0.26 | 0.70 | 0.80 | 6.80 | 8.60 | 89 |
2.50 x 2 | 0.26 | 0.80 | 1.00 | 8.40 | 10.60 | 137 |
0.50 x 3 | 0.21 | 0.60 | 0.80 | 5.80 | 7.20 | 55 |
0.75 x 3 | 0.21 | 0.60 | 0.80 | 6.00 | 7.60 | 69 |
1.00 x 3 | 0.21 | 0.60 | 0.80 | 6.30 | 8.00 | 80 |
1.50 x 3 | 0.26 | 0.70 | 0.90 | 7.40 | 9.40 | 110 |
2.50 x 3 | 0.26 | 0.80 | 1.10 | 9.20 | 11.40 | 164 |
0.50 x 4 | 0.21 | 0.60 | 0.80 | 6.60 | 8.30 | 66 |
0.75 x 4 | 0.21 | 0.60 | 0.80 | 6.90 | 8.60 | 80 |
1.00 x 4 | 0.21 | 0.60 | 0.90 | 7.10 | 9.00 | 98 |
1.50 x 4 | 0.26 | 0.70 | 1.00 | 8.40 | 10.50 | 138 |
2.50 x 4 | 0.26 | 0.80 | 1.10 | 10.10 | 12.50 | 205 |
0.50 x 5 | 0.21 | 0.60 | 0.90 | 7.00 | 8.90 | 80 |
0.75 x 5 | 0.21 | 0.60 | 0.90 | 7.40 | 9.30 | 98 |
1.00 x 5 | 0.21 | 0.60 | 0.90 | 7.80 | 9.80 | 115 |
1.50 x 5 | 0.26 | 0.70 | 1.10 | 9.30 | 11.60 | 162 |
2.50 x 5 | 0.26 | 0.80 | 1.20 | 11.20 | 13.90 | 244 |