Online Support

+0909-445538

24 hours online support our customer.replacing a multi-lined selection of text.

Single Core Building Wires

Single Core Building Wires

Uni Flex Cables Industries.

  • Product Name :- Single Core Building Wires
  • Product Category :- General Wires and Cables
  • Make an Inquiry
  • Maintains the Quality of Products

Product Application:strong> General Wiring, Industrial Wiring in Conduits, protected installation in switchgear, lighting and appliances. Product Standard:strong> As per SANS 1507-2&3, ZS 688-2&3. Type of Conductor:strong> As per SANS:1411-1, ZS 756-1. Type of Insulation Material:strong> PVC as per SANS: 1411-2 , ZS 756-2. Insulation Type:strong> General Purpose PVC, Heat Resistant PVC, Flame Retardant PVC, Flame Retardant Low Smoke Material Insulation Colour:strong> RED, YELLOW, BLUE, BLACK, GREEN/YELLOW and all other colours as per ZS 688/SANS 1507 Voltage Rating:strong> 600/1000V Maximum Conductor Temperature:strong> 70°C, 85°C,105°C Short Circuit Rating:strong> 160°C

Single Core Building Wires with Solid Copper Conductor having Voltage Rating 600/1000V

Nominal Cross Section Area of Conductor – – (Sqmm)Conductor ConfigurationNominal Thickness of the Insulation – – (mm)Overall Diameter of Insulated Wire – – (mm)Current Carrying Capacity in Air – – (Amps)Maximum DC Resistance at 20°C – – (Ohm/KM)Minimum Insulation Resistance at 23°C(MW-KM)Approximate Weight of Finished Insulated Wire(Kg/KM)
Nos. of Wires/ Wire Size(Nos./mm)Solid Conductor Diameter Approx. (mm)
1.001/1.131.130.802.601518.102519
1.501/1.381.380.803.001912.102422
2.501/1.781.780.803.40277.412032
4.001/2.252.251.004.25354.611951
6.001/2.782.781.004.80453.081772

Single Core Building Wires with Stranded Copper Conductor having Voltage Rating 600/1000V

Nominal Cross Section Area of Conductor – – (Sqmm)Conductor ConfigurationNominal Thickness of the Insulation – – (mm)Overall Diameter of Insulated Wire – – (mm)Current Carrying Capacity in Air – – (Amps)Maximum DC Resistance at 20°C – – (Ohm/KM)Minimum Insulation Resistance at 23°C(MW-KM)Approximate Weight of Finished Insulated Wire(Kg/KM)
Nos. of Wires/ Wire Size(Nos./mm)Stranded Conductor Diameter Approx. (mm)
1.007/0.431.290.802.901518.102520
1.507/0.531.590.803.201912.102423
2.507/0.672.010.803.60277.412034
4.007/0.852.551.004.55354.611953
6.007/1.043.121.005.10453.081776
10.007/1.354.051.006.00621.8314117
16.007/1.705.101.007.00871.1511175
25.007/2.146.421.209.001160.72711271
35.007/2.527.561.2010.101390.5249367
50.007/3.009.001.4012.001710.3879518
70.0019/2.1610.801.4013.802200.2688710
95.0019/2.5212.601.6016.002730.1938962
120.0019/2.8414.201.6017.603130.15371205
150.0019/3.1615.801.8019.603650.12471500
185.0037/2.5217.642.0021.804290.099171860
240.0037/2.8620.022.2024.605070.075472400
300.0037/3.2022.402.4027.405820.060172996
400.0061/2.8825.922.6031.506730.047063955

Sustainability
Highest Quality Policy
Safety Policy
Vision

Always be the first choice for customers, employees and society of generations to come.

Mission

"Be a world's premier solution-driven supplier with outstanding expertise, innovative solutions and best quality."

Core Values

The guiding principle of organization: Five core Values